
A Southern California county has relied on VAPEX at the same lift station since 2005, upgrading twice and staying with VAPEX each time.
Most odor control stories end at installation day. This one keeps going. It follows a county that solved its odor problem in 2005, kept it solved for years, and then chose VAPEX again in 2013 and in 2023.
That kind of repeat decision says more than any single reading could. It shows a utility that trusts the technology over the long haul.
The Challenge: Persistent Odor at a County Lift Station
The county was having difficulties with odor at a pump station wet well.
Lift stations collect wastewater that can sit long enough to go septic. That releases hydrogen sulfide (H2S) and other odor compounds, which escape through vents and hatches into the surrounding area.
The county needed a reliable fix it could count on for years, not a short-term patch.
The Solution: Three VAPEX Generations at One Site
The county’s VAPEX system has evolved across three installations:
| Year | System | What happened |
|---|---|---|
| 2005 | VAPEX 1500 | Installed to address the odor problem; odors were eliminated |
| 2013 | New VAPEX 1500 | After 8 years of service, upgraded to a new 1500 with updated features |
| 2023 | VAPEX NANO with 2 HV nozzles | Upgraded again to VAPEX’s current-generation unit |
The NANO is built for confined wastewater spaces such as lift stations and wet wells. It produces hydroxyl radicals that oxidize H2S, mercaptans, amines and other odor compounds at the source, with no chemicals to store or dose.
| NANO spec | Value |
|---|---|
| Maximum oxidant output | 20 g/hr |
| Maximum nozzles | 2 |
| Maximum treatment volume | 10,000 ft³ (application dependent) |
| HV nozzle air output | 30–40 CFM |
| HV nozzle water use | 8 gal/hr |
This site runs two HV nozzles, which is the NANO’s full nozzle capacity.
The Results: Odors Eliminated, and a Customer Who Keeps Coming Back
The first VAPEX 1500 eliminated the odors. It then ran for 8 years before the county chose to upgrade.
The strongest result here is the county’s own decisions. Twice, when it was time to update equipment, the county stayed with VAPEX: first with a newer 1500 in 2013, then with a NANO in 2023.
That adds up to nearly two decades of odor control at a single site, carried across three equipment generations.
What This Means for Your Utility
Odor control is a long-term commitment, and this county’s experience shows what that can look like:
- Look for proven longevity. The original unit served for 8 years before the county chose to upgrade.
- Upgrade, don’t restart. Moving to newer VAPEX models let the county add features without changing approach.
- Treat at the source. Hydroxyl radicals oxidize odor compounds inside the wet well, before they reach the community.
- Stay chemical-free. No tanks, deliveries or dosing to manage at the station.
Looking for Odor Control That Lasts?
Whether you’re installing your first system or upgrading an aging one, VAPEX can help you find the right fit.
Talk to a VAPEX application specialist about your site, or find your local rep with the Representative Locator. You can also call 407-977-7250 or email info@govapex.com.



